Overview
The ZIRKON® ONE sensor series is designed specifically for the NEON® ONE platform. All sensors feature a uniform design with intelligent connectivity for reliable water quality measurement.
Key features of all ZIRKON® ONE sensors:
- 8-pole Snap-In Connector – Uniform connection for all sensor types
- One-hand & blind installation – Easy sensor replacement
- Integrated memory – Stores calibration data and sensor identification
- Advanced diagnostics – Tracks operational hours and temperature events
- Direct connection to NODE – Digital signal conversion at the sensor
Available Sensors
ZIRKON® ONE DIS sensor family overview
| Sensor | Measurement | Range |
|---|---|---|
| ZIRKON® ONE FT | Flow monitoring & Temperature | 0–50°C |
| ZIRKON® ONE pH Universal | pH value | 0–14 pH |
| ZIRKON® ONE DIS | Free chlorine, Chlorine dioxide, Ozone | 0–20 mg/L |
| ZIRKON® ONE TCL/Biocides | Total chlorine, Biocides | 0–20 mg/L |
| ZIRKON® ONE ORP Universal | Redox potential (ORP) | −1500 to +1500 mV |
| ZIRKON® ONE EC | Conductivity | 0–3 mS/cm |
| ZIRKON® ONE Sulfite | Sulfite concentration | 0–20 mg/L |
Sensor Details
ZIRKON® ONE FT (Flow & Temperature)
ZIRKON® ONE FT
Included in every KRYPTON® ONE system. Monitors water flow and measures temperature for compensation of other measurements.
- Function: Flow monitoring + temperature measurement
- Position: Dedicated slot in STABIFLOW® ONE
- Purpose: Ensures stable flow conditions and provides temperature compensation
ZIRKON® ONE pH Universal
High-precision pH sensor for universal water quality applications.
- Range: 0–14 pH
- Calibration: 2-point calibration with buffer solutions (pH 4, 7, or 10)
- Applications: Drinking water, process water, pools
ZIRKON® ONE DIS (Disinfection)
Digital sensor for disinfection measurement using amperometric technology.
- Measures: Free chlorine, Chlorine dioxide, Ozone
- Range: 0–20 mg/L
- Calibration: Water sample calibration with reference measurement (DPD)
- Special: Supports ASR® (Automatic Sensor Cleaning)
- Installation note: Must be installed in the last chamber of STABIFLOW® ONE when using ASR®
ZIRKON® ONE TCL/Biocides
Specialized sensor for total chlorine and biocide monitoring.
- Measures: Total chlorine, Biocides
- Range: 0–20 mg/L
- Calibration: Water sample calibration with reference measurement
- Applications: Process water, cooling water, industrial applications
ZIRKON® ONE ORP Universal
High-accuracy oxidation-reduction potential sensor.
- Range: −1500 to +1500 mV
- Calibration: Typically not required; can be validated with redox standard solutions (e.g., 220 mV or 468 mV)
- Applications: Disinfection monitoring, process control
ZIRKON® ONE EC (Conductivity)
High-accuracy conductivity sensor for water quality monitoring.
- Range: 0–3 mS/cm
- Calibration: Standard conductivity solutions (e.g., 1413 μS/cm, 500 μS/cm) or reference measurement
- Applications: RO systems, process water, quality monitoring
ZIRKON® ONE Sulfite
Digital sensor for sulfite concentration measurement.
- Range: 0–20 mg/L
- Calibration: Water sample calibration
- Applications: Boiler water treatment, deoxygenation processes
Sensor Installation
- Insert the sensor into the threaded port on STABIFLOW® ONE
- O-rings are pre-installed – hand-tighten only
- Attach the NEON® ONE NODE onto the sensor head (click-fit)
-
Verify NODE LED shows solid green
Sensor Maintenance
| Task | Frequency |
|---|---|
| Visual inspection | Weekly |
| Cleaning | Every 2 weeks or as needed |
| Calibration check | Weekly (compare with reference) or as needed |
| Calibration | As needed based on drift |
| Sensor replacement | Typically 6–12 months (application dependent) |
Ordering Information
| Item Number | Sensor |
|---|---|
| S25137030K | ZIRKON® ONE FT |
| S25131110K | ZIRKON® ONE pH Universal |
| S25135140K | ZIRKON® ONE DIS |
| S25135440K | ZIRKON® ONE TCL/Biocides |
| S25135220K | ZIRKON® ONE ORP Universal |
| S25130002K | ZIRKON® ONE EC |
| S25135151K | ZIRKON® ONE Sulfite |